한국해군과학기술학회
[ Article ]
Journal of the KNST - Vol. 2, No. 2, pp.45-48
ISSN: 2635-4926 (Print)
Print publication date 30 Sep 2019
Received 08 May 2019 Revised 24 Jun 2019 Accepted 12 Jul 2019
DOI: https://doi.org/10.31818/JKNST.2019.09.2.2.45

소화 Foam 혼합을 위한 선박용 소화장치 In-Line Eductor의 성능 검토

배징도1, * ; 이규명1 ; 황태규1 ; 김정환1 ; 공길영1 ; 이창규2 ; 이찬우2
1(재)한국조선해양기자재연구원
2(주)나브텍
Performance Review of In-Line Eductor of Hose Reel Foam Station for Fire Extinguishing System of Ship
Jing Do Bae1, * ; Kui Ming Li1 ; Tae Kyu Hwang1 ; Jeong Hwan Kim1 ; Gil Young Kong1 ; Chang Kyu Lee2 ; Chan Woo Lee2
1Korean Marine Equipment Research Institute
2Navutec

Correspondence to: *Jing Do Bae Tel: +82-51-400-5132 E-mail: zinx@komeri.re.kr

© 2019 Korea Society for Naval Science & Technology

초록

Hose reel station은 해양플랜트의 헬리데크나 선박에 설치되어 소화액과 물이 혼합된 소화 foam을 방출하여 화재 발생 시 화재를 진압하는 용도로 사용된다. In-Line Eductor는 hose reel foam station의 주요 부품으로 물과 소화액을 혼합하는 역할을 수행한다. 물과 소화액의 과 혼합은 방출 후 추가적인 환경오염으로 이어질 수 있으며 혼합액의 방출 거리를 줄이는 등의 문제를 야기할 수 있어 효과적인 화재 진압과 2차 오염 방지를 위해서 물과 소화액의 적절한 혼합비는 매우 중요하다. In-Line Eductor는 hose reel station에 장착되어 물과 소화액을 혼합 후 호스로 전달하는 역할을 한다. 본 논문에서는 In-Line Eductor의 설계 인자를 전산 해석을 통해 검토하여 더 나은 설계를 얻기 위한 기초자료로서 활용할 수 있도록 한다.

Abstract

The hose reel station is installed on the heli-deck of ship or offshore plant to release extinguishing foam mixed with water and extinguishing liquid. In-line eductor is the main part of hose reel foam station, which mixes water and extinguishing liquid. The over-mixing of liquid can lead to additional environmental pollution after release and can cause problems such as reducing the discharging distance of the mixed solution. Therefore, proper mixing ratio of water and extinguishing liquid is very important for effective fire extinguishing and secondary pollution prevention. The In-line eductor is installed in the hose reel station to mix water and extinguishing liquid and deliver it to the hose. In this paper, the design factors of the In-line eductor are reviewed to identify the factors influencing the mixing ratio of water and extinguishing liquid to obtain a better design by computational analysis.

Keywords:

Fire Extinguishing System, Hose Reel Foam Station, In-Line Eductor, Fire Extinguishing Foam, Mixing Ratio

키워드:

소화 시스템, 호스 릴 폼 스테이션, 인-라인 혼합기, 소화폼, 혼합률

Acknowledgments

본 논문은 2018년도 산업통상자원부의 재원으로 경제협력권산업육성사업의 지원을 받아 수행된 연구임(P0002252, IMO(MSC, 1471) 및 SOLAS II-2장(FSS code 17) 개정에 따른 MED 인증 획득을 위한 헬기 착륙지역의 모듈러형 스마트 친환경 포말 소화시스템 개발)

References

  • Jin-Ho Kim, Lui-Ming Li, Yoon-Hwan Choi, Yeon-Won Lee, “Characteristic analysis of multiphase flow in ejector of fresh water generator“, The Korean Society of Mechanical Engineer 2012 spring conference, 2012, 84-86.
  • ANSYS ver18.0, on-line help